    Transformer Enameled Copper Wire Using IEC Standard Class 155/180

    Ask Lasest Price
    Brand Name : Ruiyuan
    Model Number : 0.08mm
    Certification : UL/ISO9001/ISO14001/RoHS/Reach
    Price : Negotiation
    Payment Terms : Negotiation
    Supply Ability : 10Ton/week
    Delivery Time : 2-15 days
    • Product Details
    • Company Profile

    Transformer Enameled Copper Wire Using IEC Standard Class 155/180

    Transformer Enameled Copper Wire Using IEC Standard Class 155/180

    Electric motors contain coils to produce the required magnetic fields. For a given size of motor frame, high conductivity material reduces the energy loss due to coil resistance. Poorer conductors generate more waste heat when transferring electrical energy into kinetic energy.

    Because of its high electrical conductivity, copper is commonly used in coil windings, bearings, collectors, brushes, and connectors of motors, including the highest quality motors. Copper's greater conductivity versus other materials enhances the electrical energy efficiency of motors. For example, to reduce load losses in continuous-use induction-type motors above 1 horsepower, manufacturers invariably use copper as the conducting material in windings. Aluminium is an alternate material in smaller horsepower motors, especially when motors are not used continuously.

    Item
    Transformer Enameled Copper Wire Using IEC Standard Class 155/180
    Key wordTransformer Enameled Copper Wire Using IEC Standard Class 155/180
    Coating
    Polyurethane
    Thermal grade
    155
    Characteristics
    Technical requests
    Test Results
    Sample 1
    Sample 2
    Surface
    Good
    OK
    OK
    Bare Wire Diameter
    0.080±0.002
    0.45
    0.45
    Coating Thickness
    ≥ 0.008 mm
    0.011
    0.012
    Overall Diameter
    ≤ 0.094 mm

    0.091
    0.092
    Conductor Resistance
    ≤ 3.608 Ω/m
    3.456
    3.443
    Elongation
    ≥ 16 %
    19
    19
    Breakdown Voltage
    ≥ 425 V
    1578
    1496
    Pinhole Test
    ≤ 5 holes/5m
    0
    0
    Continuity
    ≤ 40 holes/30m
    0
    0
    Test Items
    Technical Requests
    Results
    Adhesive
    Coating layer is good
    OK
    Cut-through
    200℃ 2minsno breakdown
    OK
    Heat Shock
    175±5℃/30minno crack
    OK
    Solder Ability
    390± 5℃ 2SecNo blister, no expansion, no shed
    OK
    Quality Transformer Enameled Copper Wire Using IEC Standard Class 155/180 for sale